HOPPE: Fire door FAQs – A guide to fire and escape door hardware

  • 4 Nov 2021

HOPPE (UK) shares some of the questions that its technical teams are asked about fire doors and offers advice for specifying compliant door hardware in public buildings…

Can you turn any door into a fire door?

No, a fire door is designed to withstand fire for a set period of time, and it must have fire test evidence to prove this performance. This will usually be a certificate of performance, showing that the door can withstand fire for a certain length of time.

Fire doors have a minimum fire rating of 30 minutes (FD30), but some steel fire doors can achieve 240 minutes of fire resistance (FD240).

What hardware do I need?

There are three pieces of operational hardware that are critical to a fire door’s performance: hinges, door closing devices and locks. In a fire, these products help to close and secure the doors in the frame for a period of time to allow intumescent protection in the frame to expand and fill the gaps around the door.

To conform to EN1154, the smallest door closer that can be used on a fire door is a size 3. The heavier the door, the more powerful the closer must be. The smallest size 3 is up to 60kg and 950mm wide and the largest size 6 up to 120kg and 1400mm wide. 

What is panic and emergency exit hardware and do I need it?

Depending on where the door is located, you may need panic or emergency exit hardware. The type of hardware required will depend on the building’s type, application, its occupation levels, and where the door is in the building. For fire doors on an escape route, panic or emergency exit hardware is mandatory.

Emergency exit hardware is mainly used in buildings where users are familiar with exit routes, such as offices, and are not accessible to the public. Devices for these doors could be a simple push pad type device or a lever handle operating a mortice escape lock or nightlatch. 

Panic hardware is used when the general public has access to the building and may not be familiar with the exit routes, for example in hospitals and community buildings. This applies to any room with a capacity of over 60.

Any doors in areas that are accessible to the public must have a device fitted that is operable by a horizontal bar that covers at least 60% of the overall door width. As well as being easier to see and use, it also adds another layer of safety functionality in the event of an emergency

What signs do I need for my fire door?

There are three types of signs for use on fire doors:

 – Fire Door Keep Shut – for self-closing doors used for passage of people
 – Fire Door Keep Locked – for doors which are locked shut and only used occasionally
 – Automatic Fire Door Keep Clear – for doors which are held open using a legal device or are swing-free but revert to self-closing when a fire alarm is activated

I’m about to refurbish my building, what do I need to consider?

If replacing any fire door hardware, the new components must be equal to or better than the fire/mechanical performance of the door.

To tell if a product is ‘like for like’, look at the tested elements and the certification for the products. Check what type of door the ironmongery is tested for use on. A product that has been fire tested for use on an FD30 is not necessarily suitable for use on an FD60 and vice versa (without prior testing on that type of door).

Remedial work should not include any removal of intumescent materials from the door unless damaged. Any replacement of hardware intumescent kits should be the exact same material, size and thickness.

Any works should be carried out by a competent person and should be signed and countersigned by the tradesperson completing the installation and the fire door inspector. All materials used should be clearly listed and a certification file compiled for future reference.

How often should I check and maintain fire door hardware?

A fire door needs regular maintenance and checks to prevent and address issues that could impact performance. There is not a specific frequency stated within law, but HOPPE (UK) recommends at least once per year.

When inspecting the ironmongery on a fire door, here are some key things to check:

 – CE marked hinges are firmly fixed with no missing screws
 – Seals are fitted at the top and sides of the door
 – The door closer shuts the door firmly into the latch from any position

If in doubt about any fire door hardware, consult with the original door manufacturer or contact one of HOPPE (UK)’s Guild of Architectural Ironmongers (GAI) qualified experts for advice on 01902 484 400.

Leave a Reply

Latest news

Acoustic panelling from Troldtekt creates striking effect at 6 Embassy Gardens

Wood wool acoustic panelling with a black finish from Troldtekt has been specified throughout 6 Embassy Gardens at Nine Elms in London

Posted in Acoustics, Noise & Vibration Control, Articles, Ceilings, Posts

Passenger lifts from Stannah elevate safety and accessibility at Elizabeth Tower

Two lifts, designed and manufactured in the UK by Stannah now take pride of place as part of London’s Elizabeth Tower restoration project

Posted in Articles, Lifts, Posts, Restoration & Refurbishment, Retrofit & Renovation

Senior Architectural Systems appoints new major projects manager

Aluminium windows, doors and curtain wall solutions manufacturer, Senior Architectural Systems has appointed Mark Rossouw to the newly created role of major projects manager

Posted in Articles, Building Industry News, Doors, Posts, Recruitment, Windows

Aluminium architectural louvre products from Kingfisher now available on NBS Source

Kingfisher Louvres has made four of its most popular screening and single bank weather louvres available to specify via the NBS Source platform

Posted in Air Conditioning, Articles, Facades, Heating, Ventilation and Air Conditioning - HVAC, Posts, Ventilation