A major part of the UK’s commitment to meeting its targets for carbon reduction is being driven by a tightening of the Building Regulations surrounding energy efficiency standards for homes.
The Ministry of Housing, Communities and Local Government (MHCLG) argues that by making our buildings more energy efficient and embracing smart technologies, we can cut energy bills, reduce demand for energy, and boost economic growth while meeting our targets for carbon reduction and maintaining healthy environments. As such it has introduced ‘The Future Homes Standard’ to ensure all new homes achieve a 30% improvement in energy efficiency standards by 2025.
The latest Building Regulations, which came into effect in June 2022, aims at achieving these targets and comprises of five Approved Documents.
Manufacturers, architects, specifiers and customers looking to install rooflights and roof windows will be most interested in uplifts to the Approved Document L, Conservation of fuel and power Vol 1: Dwellings.
For rooflights, skylights and roof windows (of which the definition is crucially important), the relevant consideration is the thermal transmittance. This is measured as a U-value in units of W/m²K, which stands for Watts/meter square Kelvin. The lower the U-value the more efficient the construction is at keeping heat flow through the structure to a minimum.
The regulations deem the worst acceptable U-values to be 2.2W/(m2K) for rooflights and 1.6 W(m2K) for roof windows.
To correctly assess whether an element meets the limiting U-value figure, the U-value must be calculated for the element in the appropriate plane – either horizontal or vertical. Now this makes a big difference, as testing the same product in either a horizontal or vertical position will make a significant difference to the resulting U-value figure. With the vertical position providing a much lower (better) U-value figure.
This is where the definition of the terms and roof window prove crucial in determining how they should be tested and what the relevant U-value should be for each.
According to the Approved Document the following definitions apply:
Rooflight: A glazed unit installed out of plane with the surface of the roof on a kerb or upstand. Also sometimes referred to as a skylight.
Roof window: A window installed in the same orientation as, and in plane with, the surrounding roof.
Therefore, while we might refer to our product as a rooflight or skylight, the official terminology for a conservation rooflight, which is designed to sit flush within a roof line, should be a roof window.
According to the Approved Document, the U-values for roof windows should be calculated based on a vertical position. For rooflights, U-values should be calculated based on a horizontal position.
Further guidance in the Building Research Establishment’s BR 443 tells us that U-values for roof windows and rooflights are usually quoted for the in the vertical plane. This allows comparison of different products that could be used at different inclinations. However, for the purposes for calculating heat losses from buildings, U-values should relate to the plane of the component as installed in the building.
This can be done by calculating the U-value of rooflights and roof windows, allowing for the angle of the roof in respect of both surface resistances and gas space resistances. Alternatively the following adjustments can be made to U-values assessed for the component in the vertical plane:
It is important to understand that there is much ambiguity surrounding rooflights, skylights and roof windows and the U-values quoted by various manufacturers. The much-coveted U-value figure has become a powerful sales tool for those claiming to be ‘the best performing’ or ‘most thermally efficient’ rooflight on the market and you will often see figures advertised that are misleading. Some companies confuse the issue by quoting the centre pane figure for the glass, rather than a whole frame U-value, which is the legal requirement. In any case, caution is advised when researching the various products available and you should always request evidence to support the thermal performance claims made.
U-value calculations for roof windows and rooflights must be undertaken by an approved UKAS accredited product certification agency, who will calculate accurate thermal performance figures based on the individual make up of components in the product’s construction.
While it is not always the case, it stands to reason that the majority of conservation rooflights are installed in traditional properties, barn conversions, and Listed buildings. If your project involves such a property, you may find that there are exemptions to these new regulations.
The Approved Document states that the energy efficiency of historic and traditional dwellings should be improved only if doing so will not cause long-term deterioration of the building’s fabric or fittings.
New extensions to historical and traditional dwellings should comply fully with the energy efficiency standards, unless there is a need to match the external appearance or character of the extension to that of the host building. In which case, the work should comply with standards in the approved document to the extent that it is reasonably practicable.
In determining whether full energy efficiency improvements should be made, the building control body should consider the advice of the local authority’s conservation officer.
Additional guidance is available in Historic England’s Energy Efficiency and Historic Buildings: Application of Part L of the Building Regulations to Historic and Traditionally Constructed Buildings.
For more information download ‘The Ultimate Guide to Conservation Rooflights’ – an independent guide to everything you need to know about specifying conservation rooflights – available exclusively on the Stella Rooflight website.
Alex Tremlett, Insight Data’s Commercial Director, discusses the challenges for construction firms in 2025 and shares six strategies for success…
Posted in Articles, Building Industry News, Building Services, Information Technology, news, Research & Materials TestingIncoming governments, especially those with significant mandates, inevitably come into power on a tidal wave of optimism coupled with hope that ‘Things can only get better’. Andrew Scott, MD of construction-focused, full-service agency Purplex, talks…
Posted in Articles, Building Industry News, Building Services, Information Technology, news, Posts, Research & Materials TestingPop Up Power Supplies has installed 13 new electricity units at The Hepworth Wakefield – read more in this article…
Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Case Studies, Civil Engineering, Facility Management & Building Services, Garden, Hard Landscaping & Walkways, Landscaping, Posts, Restoration & Refurbishment, Retrofit & RenovationUK-based OPT Services has unveiled SlimLine™ Capping, a groundbreaking fibre cable protection solution that promises to deliver significant environmental and installation advantages to the fibre optic industry.
Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Facility Management & Building Services, Information Technology, Innovations & New Products, Sustainability & Energy Efficiency