Technical Services Manager for Swish Building Products, David Osborne, discusses factors which can seriously affect the structural viability of roofline products.
With the country receiving an average of almost 900mm of rain each year, how we capture, manage and dispose of surface water from a building’s roof and stop it getting into vulnerable areas around the eaves, is crucial. However, these are one of the most neglected considerations of house design in the UK.
Rain landing on the roof must be channelled and disposed of to prevent moisture ingress to the supporting structure. Therefore, the system of guttering, down pipes and the supporting fascia assembly needs careful planning.
David recommends the use of cellular PVC for the roofline as it is most cost effective, long-lasting and requires no maintenance, suitable for exposed and inaccessible locations at the eaves.
It is also advised that you cover the point of union of the roof tiles and the brick wall as it must be defended against water and wind ingress whilst allowing proper ventilation of the roof void. Ventilation is crucial as the average attic is the ideal micro-world in which mould and rot can take hold if the moisture is not kept moving.
PVC roofline systems (fascias, soffits, bargeboards and all the associated ventilation components) protect the eaves while fully venting them. Continuous venting units sit on top of the fascia board and support the roofing felt and the lower row of tiles – meaning no slots or ugly vent discs set into the soffit board.
PVC roofline systems also provide both visual and physical support for the other essential components in rainwater management – guttering and downpipe systems.
To choose a gutter system with sufficient flow capacity you must work out what the gutter system has to cope with.
To calculate the quantity of rainwater that might run off the roof, you must decide [a] The rainfall intensity that the system must cope with [litres per hour per m2]. [b] Calculate the roof area to be drained. [effective roof area m2]. Once that’s done we must choose a gutter system with sufficient flow capacity (litres per second) and finally decide on the system layout including the fall of the gutter and the number and position of outlets required to maximise the flow.
BS 12056:2000 sets out the method for calculating roof drainage. The standard states that domestic gutter systems should be designed for a storm event that is likely to occur once a year with an intensity of 75mm per hour per m2 or a flow rate of 0.021 litres per second.
However, anecdotal evidence tells us that parts of the country are now experiencing much more intense “50 year plus’ events every few years.
The area of roof that drains into any one gutter can be calculated by using (H/2) + WxL or LxWxPitch Factor. The area of roof to be drained should now be compared with the maximum area that the manufacturer claims a given gutter type is able to drain.
If the figure for the chosen gutter is too low the designer can increase the fall of the gutter. However, water coming off the tiles is more likely to overshoot a tilted gutter at the lower end. This may not be an option though where a shallow fascia is fitted. In addition, once the length of a gutter section exceeds 50 times the height of water that it can realistically hold, the flow efficiency starts to decline.
The outlet point can be moved to a central position, on the other hand. Generally speaking, down pipes have significantly more capacity than gutter units and a centrally places outlet in most gutter runs will increase the gutter’s drainage capacity.
Underground drain points are unlikely to be available though, directly below gutter outlet positions that are chosen late in the design process.
Finally, the designer can select a system with a higher capacity. David suggests that “over specing” guttering should be seriously considered for the future.
Contact:
Swish Building Products,
Pioneer House, Mariner,
Lichfield Road Industrial Estate,
Tamworth,
Staffordshire,
B79 7TF
Visit Swish Building Products' website
The latest Builders Merchant Building Index (BMBI) report shows builders’ merchants’ value sales in October were up +1.2% compared to the same month last year.
Posted in Articles, Bathrooms & Toilets, Bricks & Blocks, Building Associations & Institutes, Building Industry News, Building Products & Structures, Building Services, Building Systems, Civil Engineering, Cladding, Concrete, Cement, Admixtures, Drainage, Drainage Services, Floors, Garden, Hand Tools, Hard Landscaping & Walkways, Health & Safety, Heating Systems, Controls and Management, Heating, Ventilation and Air Conditioning - HVAC, Information Technology, Interior Design & Construction, Interiors, Landscaping, news, Paints, Paints, Coatings & Finishes, Pipes, Pipes & Fittings, Plant, Equipment and Hire, Plumbing, Power Tools, Publications, Research & Materials Testing, Restoration & Refurbishment, Retrofit & Renovation, Site Preparation, Sustainability & Energy Efficiency, Timber Buildings and Timber Products, Walls, Waste Management & RecyclingKids’ Village is delighted to have partnered with GEZE UK as their 2025 charity of the year – find out more via the article…
Posted in Access Control & Door Entry Systems, Architectural Ironmongery, Articles, Building Industry Events, Building Industry News, Building Products & Structures, Building Services, Charity work, Doors, Facility Management & Building Services, Health & Safety, Restoration & Refurbishment, Retrofit & Renovation, Security and Fire Protection, WindowsThe Encon Group, the leading independent distributor of building materials, is pleased to announce that it has been awarded Silver membership of The 5% Club by the 2024/25 Employer Audit Scheme.
Posted in Articles, Awards, Bricks & Blocks, Building Associations & Institutes, Building Industry Events, Building Industry News, Building Products & Structures, Building Regulations & Accreditations, Building Services, Building Systems, Civil Engineering, Cladding, Concrete, Cement, Admixtures, Facades, Hard Landscaping & Walkways, Health & Safety, Insulation, Landscaping, Plant, Equipment and Hire, Recruitment, Restoration & Refurbishment, Retrofit & Renovation, Site Preparation, Training, WallsLocated in Charlton, South London, SWA member West Leigh was established during the Blitz, in 1943. During the destruction in London, the company helped in repairing windows and facades that had been damaged by bombings throughout the city.
Posted in Articles, Building Associations & Institutes, Building Industry News, Building Products & Structures, Building Services, Building Systems, Case Studies, Facades, Glass, Glazing, Restoration & Refurbishment, Retrofit & Renovation, Steel and Structural Frames, Walls, Windows