For any below ground structure, basement drainage should always be considered essential, Delta Membranes explain here…
Even with site investigations at the planning stage, this is only a snap shot in time. Groundwater is expected to come to bear against the structure at some point during its service life.
BS8102:2009 states “…waterproofing measures should be designed on the basis of water to the full height of the retained ground at some time during the structure’s life…”
Groundwater is the most commonly forgotten aspect of the Water Cycle, as it is not readily seen. The Water Cycle is the constant movement of water through the environment, travelling as slowly as a metre per year.
Evaporation of ocean water condenses into clouds ready for rainfall across the land. After rainfall, the surface rainwater flows back into rivers and the sea.
Water pressures acting on the external retaining wall system and water pressures below the basement slab should always be key factors for reducing risk when designing a robust waterproofing solution.
The design should enable the system specified to withstand a pre-determined head of water or control any water ingress before it reaches the structure.
Type C waterproofing systems do not provide a hydrostatic barrier against water ingress but provides a controlled means of water management.
There are two main systems, both work alongside a Type C Cavity Drainage System to collect and manage water these are Perimeter Drainage and Modular Drainage.
Without fail, the most popular specified system is Perimeter Drainage. All drainage systems for a Type C cavity drain system should be designed specifically for each site/project – perimeter channel, modular or a combination of both, all need to be maintainable.
Drainage channels are water collection conduits designed to manage and control water ingress. These channels are installed around the perimeter of a basement, cellar or below ground structure.
They feature a number of preformed holes that allow any water from the Type C cavity drainage system to enter the channel, then drain into a sump pump (submersible pump station) or suitable discharge point.
Once collected in the sump chamber, the groundwater can then be pumped to a safe designated point of discharge off site.
Drainage channels are available with or without upstands, and are supplied in durable straight lengths, the use of T-junctions, corner pieces, straight connectors, jetting eyes, end caps and access ports.
An alternative to perimeter drainage is a modular drainage system. Using a 110mm standard underground drainage pipe, this system is only suitable for new construction or when a new concrete slab/raft is being replaced with a reinforced slab/raft.
Drainage should be installed at uniform gradients, not less than 1:100. Piped drainage systems should be tested for leakage prior to backfilling and concreting.
When specifying and designing modular drainage systems, we would suggest liaising with Delta’s Technical Team.
When designing any basement drainage system, philosophy and approaches should always be based on functionality, quality and maintainability. All drainage systems, must be maintainable!
Delta Membrane Systems,
Delta House,
Merlin Way,
North Weald,
Epping,
Essex,
CM16 6HR
United Kingdom
Visit Delta Membrane Systems' website
Security expert Abloy UK is highlighting the urgent need for greater security and access control on highways critical infrastructure across the UK.
Posted in Access Control & Door Entry Systems, Architectural Ironmongery, Articles, Building Industry News, Building Products & Structures, Building Regulations & Accreditations, Building Services, Civil Engineering, Doors, Facility Management & Building Services, Hard Landscaping & Walkways, Health & Safety, Landscaping, Posts, Research & Materials Testing, Retrofit & Renovation, Security and Fire ProtectionBased near the historic town of Ironbridge in Shropshire, widely regarded as the birthplace of the industrial revolution, Steel Window Fittings is a market leader in high quality steel window and door handles, fittings and accessories.
Posted in Access Control & Door Entry Systems, Architectural Ironmongery, Articles, Building Associations & Institutes, Building Industry News, Building Products & Structures, Building Systems, Doors, Health & Safety, Posts, Restoration & Refurbishment, Retrofit & Renovation, Security and Fire Protection, Steel and Structural Frames, WindowsCistermiser, a leader in water management, has welcomed the ambitious water saving targets for commercial buildings recently set by DEFRA.
Posted in Articles, Building Industry News, Building Products & Structures, Building Regulations & Accreditations, Building Services, Drainage, Drainage Services, Drainage, Guttering, Soffits & Fascias, news, Pipes, Pipes & Fittings, Plumbing, Research & Materials Testing, Sustainability & Energy EfficiencyAssociated Steel Window Services (ASWS) has built a solid reputation far beyond the capital for successfully undertaking some of the most challenging fenestration contracts.
Posted in Architectural Ironmongery, Articles, Building Associations & Institutes, Building Industry News, Building Products & Structures, Building Services, Building Systems, Case Studies, Facades, Posts, Restoration & Refurbishment, Retrofit & Renovation, Steel and Structural Frames, Walls, Windows